After being placed in a chamber with 85±2℃ for 96 hours and then being placed in natural condition for 2 hours.
Allowable variation of SPL after test: ±10dB.
Low Temperature Test
After being Placed in a chamber with -30±2℃ for 96 hours and then being placed in natural condition for 2 hours.
Allowable variation of SPL after test: ±10dB.
Humidity Test
Stored in the?temperature?humidity: 60±5℃?90%--95%?environment?for 96 hours,?and then placed into?storage at room temperature for 2?hours after the?test.
Allowable variation of SPL after test: ±10dB.
Temperature Cycle Test
After being placed in a chamber with -30±2℃ for 30 minutes, products shall be placed at room temperature(25℃±10℃).After 15 minutes at this temperature, products shall be placed in a chamber at +85±2℃.After 30 minutes at this temperature, products shall be return to room temperature (25℃±10℃) for15 minutes. After 20 above cycles, products shall be measured after being placed in natural condition for 2 hours.
Allowable variation of SPL after test: ±10dB.
Drop Test
The front and side?from a height of 100mm?only?drop in the?4cm thickness of theboard?3 times each.
Allowable variation of SPL after test: ±10dB.
Vibration Test
After being applied vibration of amplitude of 1.5mm with 10 to 55 Hz band of vibration frequency to each of 3 perpendicular directions for 2 hours.
Allowable variation of SPL after test: ±10dB.
Solderability Test
Lead terminals are immersed in rosin for 5 seconds and then immersed in solder bath of 260±5℃ for 3±0.5 seconds (Except the edge of terminals).
95% min. lead terminals shall be wet with solder
Continuous electricity test
Temperature: room temperature 25 ℃
Voltage: rated voltage 3 V
Frequency: the rated frequency for 4.0 KHZ
Time: 500 hours
Allowable variation of SPL after test: ±10dB.
Erminal Strength
Pulling Test
The force of 9.8N(1.0kg) is applied to each terminal in axial direction for
10 seconds.
No visible damage and cutting off.
Typical Frequency Response Curve
TESTING METHOD
Standard Measurement conditions
Temperature:25±2℃ Humidity:45-65%
Acoustic Characteristics:
The oscillation frequency, current consumption and sound pressure are measured by the
measuring instruments shown below
In the measuring test, buzzer is placed as follows: